Deep Dive into HSS Shear and Moment Connection Examples

By Brady Golinski, PE; Mike Manor, PE; and Cathleen Jacinto, PE, SE
Technical Consultants, Steel Tube Institute

HSS is commonly utilized as a column or truss member due to its efficiency to transfer axial and torsional forces in a structure. To illustrate how to design connections to HSS members, we will dive into HSS connection examples for one common connection type and one less common connection that is difficult to find an example for in current AISC publications. Using AISC 360-2016 Specification and the 15th Edition Manual as a basis, we will step through an example for the HSS connections below. References are also made to the Steel Tube Institute’s Limit State Tables that can be downloaded here. The Limit State Tables summarize HSS local limit states to consider when designing HSS connections and outline design equations in the AISC Specification and Manual with variable substitutions specific to HSS.

  1. WF Beam to HSS Column Single Plate Shear Connection
  2. HSS-to-HSS Connection With Shear, Axial and In-Plane Moment

WF Beam to HSS Column Single Plate Shear Connection Example

The following example is a WF beam-to-HSS column single plate connection resisting shear. Design the connection per the AISC 360-16 Specification and AISC 15th Edition Manual. Loads shown are factored per LRFD load combinations.

Figure 1: WF Beam-to-HSS Column Single Plate Shear Connection
Figure 1: WF Beam-to-HSS Column Single Plate Shear Connection
HSS8x8x3/8 Column:W24x55 Beam:Bolts:
ASTM A500 Grade C
Fy = 50 ksi
Fu = 62 ksi
H = 8 in
B = 8 in
tdes = 0.349 in
A = 10.4 in2
Sx = 24.9 in3
ASTM A992
Fy = 50 ksi
Fu = 65 ksi
tw = 3/8 in
T = 20 ¾ in
¾” diameter A325-N
STD holes in beam
SSLH holes in plate

Determine the capacity of the WF beam-to-HSS column single plate connection. Note there are a number of alternate shear connections that can be utilized and are discussed in this article. A through-plate shear connection is one other shear connection option in which the single plate extends through slots in the HSS column both near side and far side. However, the through-plate connection is a more costly connection to fabricate. The single plate is typically the most cost-effective connection to resist shear.

Per AISC 15th Edition Manual page 9-17, to ensure rotational ductility in the single plate connection, the geometry and thickness of the plate are configured so that the plate will yield, the bolt group will rotate, and/or the bolt holes will elongate at failure prior to failure of welds or bolts. Per the AISC 15th Edition Manual page 10-88, check that the following dimensional limitations are met to ensure the single plate connection is consistent with a conventional configuration.

  1. There is only a single row of bolts, 2 ≤ n ≤ 12
  2. The distance from the bolt line to the weld line a = 2 in ≤ 3 1⁄2 in OK
  3. Standard or short-slotted holes are used
  4. lev = 1.25 in ≥ 1 in (from AISC 360-16 Table J3.4), leh = 1.5 in ≥ 2d = 1.5 in OK
  5. tp = 0.375 in ≤ d⁄2 + 1⁄16 = 0.4375 in OK

Since all conditions are met, this connection can be designed as a conventional configuration.

We refer to the Steel Tube Institute’s Limit State Tables to determine the limit states to check per AISC 360-16 Specification and the 15th Edition Manual. Figure 2 shows an excerpt from the Shear Limit State Tables Single Plate Connection.

Figure 2: STI Limit State Table – Shear Single Plate (Excerpt)
Figure 2: STI Limit State Table – Shear Single Plate (Excerpt)

1. Bolt Shear (Limit State Table Cell B2, Shear)

¾” A325N Bolts

ɸrn = 17.9 k/bolt                               [AISC 15th Edition Manual Table 7-1]
a = 2 in, e = a/2 = 2 in/2 = 1 in
5 bolts
C = 4.77
ɸRn = Cɸrn = 4.77(17.9)                  [AISC 15th Edition Manual Table 7-6]
85.4 k > 70 k  OK

The “T” dimension of a W24x55 is 20 ¾”
AISC 15th Edition Manual page 10-7 recommends a minimum connection length of T/2
Plate vertical dimension is Lc = (2)(1¼”)+(4)(3″) = 14½” < 20 ¾” OK
                                            Lc = 14½” > T/2 =  20.75”/2 = 10.375” OK

2. Bolt Bearing and Tearout in the Plate and Beam Web (Limit State Table Cell B4, Shear)

Since the connection geometry meets the requirements for the conventional configuration, the plate bearing and tear-out checks may be calculated with the load applied as concentric per AISC 15th Edition Manual page 10-89. Consider deformation at the bolt hole at service loads. Since the plate and W24x55 beam web thickness are both 3/8 inch, the plate calculations below can also be applied to the W24 beam web.

Bearing Rn = 2.4dtFu                              [AISC 360-16 Equation J3-6a]
Rn = 2.4 × 0.75 in × 0.375 in × 58 ksi = 39.1 k/bolt

Tear-out: Rn = 1.2lc tFu                              [AISC 360-16 Equation J3-6c]

At bottom bolt:

Bolt Bearing and Tearout in the Plate and Beam Web - Bottom Bolt Equation

At other bolts:
lc = s – dh = 3 in – (0.75 in + 0.0625 in) = 2.19 in
Rn = 1.2 × 2.19 in × 0.375 in × 58 ksi = 57.0 k/bolt

At the bottom bolt, tear-out controls; at the other bolts, bearing controls. Therefore:
ϕRn = 0.75 × (22.0 k⁄bolt + 4 × 39.1 k⁄bolt) = 134 k > Ru=70 k OK

3. Plate Shear Limit States (Limit State Table Cells B5, B6 and B10, Shear)

Shear Yield
Rn = 0.60FyAgv                              [AISC 360-16 Equation J4-3]
Agv = 14.5 in × 0.375 in = 5.44 in2
ϕRn = 1.0 × 0.60 × 36 ksi × 5.44 in2 = 117 k > Ru=70 k OK

Shear Rupture
Rn = 0.60FuAnv                              [AISC 360-16 Equation J4-4]
Anv = 0.375 × [14.5 in – 5 × (0.75 in + 0.125 in)] = 3.80 in2
ϕRn = 0.75 × 0.60 × 58 ksi × 3.80 in2 = 99.1 k > Ru = 70 k OK

Block Shear Rupture

HSS Connection Examples Bottom Block Shear Rupture Equation

4. Weld Strength (Limit State Table Cell B14, Shear)

AISC 15th Edition Manual page 10-87 offer guidance on sizing the weld between the single plate and the supporting member, our HSS column, to be 5/8tp. This develops the strength of the plate to ensure the weld is not the critical limit state. For our 3/8 inch thick single plate:

Weld size, w= 5⁄8 tp = 0.625 × 0.375 in = 0.234 in
Therefore, try 1/4″ fillet welds, each side of plate.

Check weld shear capacity (fillet weld on each side of the plate):

HSS Connection Examples - Check weld shear capacity equation

5. HSS Column Slenderness (Limit State Table Cell B16, Shear)

Confirm the HSS8x8x3/8 column selected is not classified as a slender element per AISC 360-16 Specification Table B4.1a Case 6 and 15th Edition Manual page 10-153.

For rectangular HSS sections:

HSS Connection Examples - HSS Column Slenderness equation for rectangular HSS sections

Note that the resulting b/t ratio is consistent with the AISC 15th Edition Manual Table 1-12 tabulated value for b/t for the HSS8x8x3/8 section.

6. Shear Yielding (Punching Shear) of the HSS Wall (Limit State Table Cell B19, Shear)

HSS Connection Examples - 6.	Shear Yielding (Punching Shear) of the HSS Wall equations

7. Shear Rupture at Weld (Limit State Table Cell B17, Shear)

In welded joints, the AISC Specification requires that both the weld metal and base metal be checked. Specifically for HSS, we must check that the HSS wall thickness is sufficient to adequately transfer the shear along the length of the weld, which is 14.5 inches. 

Rn = 0.6FuAnv                              [AISC 360-16 Equation J4-4]
ϕ = 0.75
ϕRn = 0.75(0.6)(62 ksi)(2 sides)(0.349 in)(14.5 in) = 282 k > Ru =70 k OK

Alternately, determine the minimum HSS column thickness required to match the 1/4-inch fillet weld strength.

HSS Connection Examples - Shear Rupture at Weld - equation to determine the minimum HSS column thickness

Therefore, the HSS8x8x3/8 column is adequate to transfer shear Vu = 70 kips at the connection.

The Steel Tube Institute’s HSS Connex tool performs the above HSS limit state checks #5 and #6.  HSS Connex does not check the plate, bolts or welds, but it can assist in ensuring the HSS wall is adequate for its local limit states. Figure 3 shows output from HSS Connex for the connection in this example.

HSS Connection Examples - HS Connex Output
Figure 3: HSS Connex Output for WF Beam-to-HSS Column Shear Connection Example

HSS-to-HSS Connection With Shear, Axial and In-Plane Moment Example

The following connection example is an HSS column supporting a cantilever HSS beam with a back span and an axial lateral pass-through force. Design the connection per the AISC 360-16 Specification and AISC 15th Edition Manual. Loads shown are factored per LRFD load combinations.

HSS Connection Examples - HSS-to-HSS Moment Connection Geometry & Loading
Figure 4: HSS-to-HSS Moment Connection Geometry & Loading
HSS10x6x3/8 Column/Chord:HSS8x6x5/16 Branch:
ASTM A500 Grade C
Fy = 50 ksi
Fu = 62 ksi
H = 10 in
B = 6 in
tdes = 0.349 in
A = 10.4 in2
Sx = 27.4 in3
Zx = 33.8 in3
Fy = 50 ksi
Fu = 62 ksi
Hb = 8 in
Bb = 6 in
tb,des = 0.291 in
Ab = 7.59 in2
Sb,x = 17.1 in3
Zb,x = 20.6 in3

Based on geometry, this connection is classified as a cross-connection with an in-plane moment. The column is the through member and is considered the “chord,” while the beams are considered the “branches.” Since the width of the chord and branches are the same, this is a matched width connection, i.e., β = 1.0 (Bb = B). This can be considered a fully restrained (FR) moment connection per AISC terminology. FR moment connections are considered sufficiently rigid, which means the change in angle between members when load is applied is negligible. In contrast, partially restrained (PR) connections can transfer moment, but the change in angle is not negligible and must be considered in the frame analysis per AISC section B3.4b(b).

AXIAL FORCE LIMIT STATES

1. HSS Chord Plastification (Limit State Table cell L1, Truss)

This is checked with AISC 15th Edition Manual Equation 9-30.

HSS Connection Examples - AISC 15th Edition Manual Equation 9-30

Refer to AISC 15th Edition Manual Figure 9-5(a). Since both the chord and the branch have a width of 6 inches, both Deep Dive into HSS Shear and Moment Connection Examples and Deep Dive into HSS Shear and Moment Connection Examples will equal zero, and therefore equation 9-30 is undefined. This makes sense since plastification occurs within the chord wall, but in this case, the branch has the same width. Therefore, the axial load transfers directly into the stiffer chord sidewalls instead of through the chord face, and this limit state is not applicable.

2. HSS Chord Shear Yielding (Punching) (Limit State Table Cell L2, Truss)

This is checked with AISC 15th Edition Manual equation 9-29.

Rn = 0.6Fy tp (2ceff + 2L)

This limit state occurs when the branch punches through the connecting face of the chord as a shear failure. Similar to plastification, the chord and branch have the same width in this example, which means a shear failure through chord cannot occur since the load will pass directly into the sidewalls. Therefore, this limit state is not applicable.

3. Local Yielding of HSS Chord Sidewalls (Limit State Table Cell L3, Truss)

Local Yielding of HSS Chord Sidewalls (Limit State Table Cell F3, Moment - AISC 360-16 Equation J10-2

4. Local Crippling of HSS Chord Sidewalls (Limit State Table Cell L4, Truss)

Local Crippling of HSS Chord Sidewalls (Limit State Table Cell L4, Truss) - AISC 360-16 Equation J10-4, K2-4 and K3-14

5. Local Buckling of HSS Chord Sidewalls (Limit State Table Cell L5, Truss)

5.	Local Buckling of HSS Chord Sidewalls (Limit State Table Cell L5, Truss) - AISC 360-16 Equation J10-8

6. Local Yielding of HSS Branches Due to Uneven Load Distribution (Limit State Table Cell L6, Truss)

This limit state occurs because the chord face that the branch is attaching to has higher stiffness near the chord sidewalls than at the middle of the chord face. To account for this, an effective width is used for the branch walls perpendicular to the chord. Only the effective area will be counted on as shown in figure 4.

Effective area:

Figure 4: Branch Wall Effective Width
Figure 4: Branch Wall Effective Width
AISC 360-16 Equation J4-1 and K1-1

7. Shear Yielding of HSS Chord Sidewalls (Limit State Table Cell L7, Truss)

This limit state applies only for inclined branches. Since θ = 90 degrees in this example, there is no projected gap, and thus this limit state is not applicable.

Controlling Axial Limit State:

Local buckling of chord sidewalls:  ϕRn = 241 k

MOMENT FORCE LIMIT STATES

1. Chord Wall Plastification (Limit State Table Cell F1, Moment)

This is checked with AISC 15th Edition Manual Equation 9-32.

1.	Chord Wall Plastification (Limit State Table Cell F1, Moment) - AISC 15th Edition Manual Equation 9-32

Referring to AISC 15th Edition Manual Figure 9-5(b), T = B and c = Bb. Since T – c = 0 will be in the denominator, equation 9-32 is undefined. Similar to item A1 under the axial section above, the force will transfer directly into the chord sidewalls, and therefore this limit state does not apply.

2. HSS Chord Shear Yielding (Punching) (Limit State Table Cell F2, Moment)

This is another limit state that checks the connecting face of the HSS chord. Since this is a matched connection where the chord and branch widths are equal, this limit state does not apply. See item 2 in the axial section above for similar discussion.

3. Local Yielding of HSS Chord Sidewalls (Limit State Table Cell F3, Moment)

Rn = Fyw tw (5k + lb )                              [AISC 360-16 Equation J10-2]

tw = k = tdes
lb = Hb
Mn = Rn × moment arm
moment arm = 0.5(Hb + 5k) = 0.5 × (8 in + 5 × 0.349 in) = 4.87 in

ϕMn = 1.0 × 50 ksi × 0.349 in × (5 × 0.349 + 8 in) × 4.87 in = 829 kin > 480 kin
OK

4. Local Buckling of HSS Chord Sidewalls (Limit State Table Cell F5, Moment)

Buckling of the sidewalls is a limit state that is only applicable to matched width (β=1.0) cross-connections when the moment is equilibrated by each branch of the cross-connection. The strength of the moment connection is increased by yielding in the adjacent tensile region. The hybrid compression buckling and tension-yielding behavior is accounted for with a local yielding check using a reduced yield strength of 0.8Fy with the same equation variable values as local yielding in moment section 3 above.

Rn = Fyw tw (5k + lb )                              [AISC 360-16 Equation 10-2]

Use ϕMn from moment check 3 above.
ϕMn = 0.8 × 829 kin = 663 kin > 480 kin
OK

5. Local Yielding of Branches Due to Uneven Load Distribution (Limit State Table Cell F6, Moment)

Mn = Mp = FyZ                              [AISC 360-16 Equation F7-1]
Z = Znet

Figure 5: Branch Wall Effective Width for Plastic Section Modulus
Figure 5: Branch Wall Effective Width for Plastic Section Modulus

This limit state occurs because the chord face that the branch is attaching to has higher stiffness near the chord sidewalls than at the middle of the chord face. Thus, the load is passed through the effective portions of the branch and an effective branch Zb is used in this equation, Zb,net (see Figure 5). A modification and derivation of this can be found in the paper “Stepped HSS T- and Cross-Connections Under Branch In-Plane and Out-of-Plane Bending” by Dr. Jeffrey Packer, available on the STI website. The following equation can be found there:

Packer, Equation 5

Controlling Moment Limit State:

Local buckling of chord sidewalls: ϕMn = 663 kin > Mu = 480 kin OK

SHEAR AND MOMENT INTERACTION

Shear and Moment Interaction - AISC 360-16 Equation K4-8

Therefore, this HSS-to-HSS moment connection is adequate to transfer the shear, axial and in-plane moment demand.

February 2023

Utilizing Technology, Expertise and Communication for Better Connection Design Outcomes

Jerod Hoffman and Eric Corwin at Meyer Borgman Johnson talk with us about adapting emerging technologies within their steel connec…

ASCE 360-16 Limit State Tables

STI created Limit State Tables to help designers navigate the significant changes to Chapter K in the AISC 360-16 Specification. T…

Wide-Flange Beam to HSS Column Shear Connections and Applicable Limit States

Many of the same connections that are used for wide flange members can also be used for HSS members with occasional variations.

linkedIn Path